Features
- Secure line flow locking device – valve is equipped with an integral locking device to secure line flow
- Blow out proof stem – the lower end of the separate stem is t- shaped to create as integral collar making the stem blow out proof
- Fire safe design- metal to metal sealing shuts off valve flow when soft sealing material are destroyed by fire
- ISO 5211 mount pad- simplifies the installation of actuators with standardized connections
- Double d stem head- insure handle lever will always be mounted correctly, parallel to the media flow, indicating valve open and close condition
- Emission free gasket - the primary gasket is emission free graphite to eliminate leakage
Size & Pressure Class
- Cl 150 – ½” To 8” (Dn15 To Dn200) Equivalne En / Din Standards
- Cl300 - ½” To 8” (Dn15 To Dn200) Equivalne En / Din Standards
- Cl600 - ½” To 2” (Dn15 To Dn50) Equivalne En / Din Standards
Reference Standards
- Design :- Bs-5351/ En-17292/ Asme B16.34
- Face To Face :- Bs-5351 / Asme B16.10
- Testing :- Bs 6755 Part-1 / Qapi 598 / En-12266
- Fire Safe :- Api 607
- Fugitive Emmission :Iso-15848/Mesc-77/312
- Nace :- Mr 01 75
- Mounting Dimensions :- Iso 5211
- Casting Inspection:- Mss Sp 53,54,55,59,93 & 94
- Forging Inspection:- Asme Section V Article 9
- Marking :- Mss Sp 25
- Radography Test :- Asme B16.34 In Accoedance To Asme Section V
- Ultrasonic Test ;- Asme B16.34 Annexure –E
- Magnetic Particle Test :- Asme B16.34 Annexure –C
- Low Temperature Impact Test :- Asme 370
- End Connections:-
- Flnaged End - Asme B16.5, En 1092-1
- Screwed End – Asme B1.20.1
- Socketweld End - Asme B16.11
- Buttweld End - Asme B16.25
Back to Ball Valves